TH384 Kabelkupplung weiblich 3 polig
Properties
Other variants (4)
| Name | Item no. | Housing | Polzahl | Steckverbindertyp | Stock | |
|---|---|---|---|---|---|---|
![]() |
TH384 Kabelstecker männlich 3 polig
Cable plug connector, male contacts
Stecker
3
|
THP.384.P1A | Cable plug connector, male contacts | 3 | Stecker | 0 |
![]() |
TH384 Kabelstecker männlich 2 polig
Cable plug connector, male contacts
Stecker
2
|
THP.384.P2A | Cable plug connector, male contacts | 2 | Stecker | 0 |
![]() |
TH384 Kabelkupplung weiblich 3 polig
Cable socket connector, female contacts
Buchse
3
|
THP.384.R1A | Cable socket connector, female contacts | 3 | Buchse | 0 |
![]() |
TH384 Kabelkupplung weiblich 2 polig
Cable socket connector, female contacts
Buchse
2
|
THP.384.R2A | Cable socket connector, female contacts | 2 | Buchse | 0 |
Matching counterpart

TH384 cable plug connector, male contacts, 3 poles
THB.384.P1AMatching pole count and contact arrangement — the termination method of each half can be chosen freely.

TH384 cable plug connector, male contacts, 3 poles
THF.384.P1AMatching pole count and contact arrangement — the termination method of each half can be chosen freely.

TH384 cable plug connector, male contacts, 3 poles
THP.384.P1AMatching pole count and contact arrangement — the termination method of each half can be chosen freely.
Description
The TH384 series joins two leads to each other — both halves sit on the cable, there is no panel mounting. In this version a piercing screw cuts through the core insulation as it is tightened and makes the contact. The series is rated 10 A at 500 V AC.
Reversed contacts
This version is the mirror image: the pin contacts sit in the cable plug (Ø 27 × 63 mm), the socket contacts in the cable socket (Ø 26.5 × 55 mm). Which side stays live in operation decides the choice — the touchable pins belong on the side that is dead once disconnected.
When piercing?
No stripping, no tool beyond a screwdriver: that saves time during field assembly. In return, the blade is designed for a given cross-section range, and a core should not be clamped repeatedly at the same spot. Where terminals are changed often, the screw version of the series is the better choice.
Pole counts
With piercing termination, 2 and 3-pole versions are available. Cable diameter runs from 7 to 12 mm.
Protection and materials
Protection rating is IP66 and IP68, impact resistance IK07. The housing is glass-fibre reinforced plastic, the contacts brass.