TH384 screw termination, reversed contacts

- Series no.:
- TH384-Screw-Reverse
- Variants:
- 6
- Series:
- TH384(6 versions)
TH384 with screw termination and reversed contacts: cable plug with pins, cable socket with sockets, 10 A at 500 V, 2 to 5 poles, IP66 and IP68.
Common properties
Available options
These properties vary within the TH384 screw termination, reversed contacts series and can be configured.
Example configurations
A selection of typical configurations from the TH384 screw termination, reversed contacts series. All 6 variants are listed in the table below.

- Housing:
- Cable plug connector, male contacts
- Steckverbindertyp:
- Stecker
- Polzahl:
- 3

- Housing:
- Cable plug connector, male contacts
- Steckverbindertyp:
- Stecker
- Polzahl:
- 2

- Housing:
- Cable plug connector, male contacts
- Steckverbindertyp:
- Stecker
- Polzahl:
- 5
- Kabelquerschnitt max. mm²:
- 1.5
All variants in the series (6)
| Name | |
|---|---|
![]() | TH384 Kabelstecker männlich 3 polig Cable plug connector, male contacts Stecker 3 |
![]() | TH384 Kabelstecker männlich 2 polig Cable plug connector, male contacts Stecker 2 |
![]() | TH384 Kabelstecker männlich 5 polig Cable plug connector, male contacts Stecker 5 |
![]() | TH384 Kabelkupplung weiblich 3 polig Cable socket connector, female contacts Buchse 3 |
![]() | TH384 Kabelkupplung weiblich 2 polig Cable socket connector, female contacts Buchse 2 |
![]() | TH384 Kabelkupplung weiblich 5 polig Cable socket connector, female contacts Buchse 5 |
Description
The TH384 series joins two leads to each other — both halves sit on the cable, there is no panel mounting. Conductors are secured with hex socket screws (M2, 0.2 Nm). The series is rated 10 A at 500 V AC with an impulse withstand voltage of 4 kV.
Reversed contacts
This version is the mirror image: the pin contacts sit in the cable plug (Ø 27 × 63 mm), the socket contacts in the cable socket (Ø 26.5 × 55 mm). When unmated, the sockets therefore sit in the coupling half.
Which side stays live in operation decides the choice. The rule of thumb: the touchable pins belong on the side that is dead once disconnected. Techno offers the other arrangement as the standard version.
Pole counts
With screw termination, 2, 3 and 5-pole versions are available. Conductor cross-section runs from 0.25 to 2.5 mm², cable diameter from 7 to 12 mm.
Protection and materials
Protection rating is IP66 and IP68, impact resistance IK07. The housing is glass-fibre reinforced plastic, the contacts brass. Contact marking 1-2-3-4-5.
Other termination methods in the same series are available as crimp and piercing versions. We assemble other configurations to order. Get in touch.